Radiometry
"Radiometry" is a descriptor in the National Library of Medicine's controlled vocabulary thesaurus,
MeSH (Medical Subject Headings). Descriptors are arranged in a hierarchical structure,
which enables searching at various levels of specificity.
The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING.
Descriptor ID |
D011874
|
MeSH Number(s) |
E05.799
|
Concept/Terms |
Radiometry- Radiometry
- Dosimetry, Radiation
- Dosimetries, Radiation
- Radiation Dosimetries
- Radiation Dosimetry
Radiation Counter- Radiation Counter
- Counter, Radiation
- Counters, Radiation
- Radiation Counters
Geiger-Mueller Counters- Geiger-Mueller Counters
- Counters, Geiger-Mueller
- Geiger Mueller Counters
- Geiger-Mueller Tube
- Geiger Mueller Tube
- Geiger-Mueller Tubes
- Tube, Geiger-Mueller
- Tubes, Geiger-Mueller
- Geiger-Mueller Probe
- Geiger Mueller Probe
- Geiger-Mueller Probes
- Probe, Geiger-Mueller
- Probes, Geiger-Mueller
- Geiger Counter
- Counter, Geiger
- Counters, Geiger
- Geiger Counters
- Geiger-Mueller Counter Tube
- Counter Tube, Geiger-Mueller
- Counter Tubes, Geiger-Mueller
- Geiger Mueller Counter Tube
- Geiger-Mueller Counter Tubes
- Tube, Geiger-Mueller Counter
- Tubes, Geiger-Mueller Counter
|
Below are MeSH descriptors whose meaning is more general than "Radiometry".
Below are MeSH descriptors whose meaning is more specific than "Radiometry".
This graph shows the total number of publications written about "Radiometry" by people in UAMS Profiles by year, and whether "Radiometry" was a major or minor topic of these publications.
To see the data from this visualization as text, click here.
Year | Major Topic | Minor Topic | Total |
---|
2024 | 0 | 1 | 1 | 2023 | 2 | 2 | 4 | 2022 | 0 | 1 | 1 | 2018 | 1 | 4 | 5 | 2017 | 2 | 5 | 7 | 2016 | 3 | 4 | 7 | 2015 | 2 | 0 | 2 | 2014 | 5 | 2 | 7 | 2013 | 1 | 1 | 2 | 2012 | 3 | 3 | 6 | 2011 | 0 | 1 | 1 | 2010 | 1 | 4 | 5 | 2009 | 3 | 1 | 4 | 2008 | 2 | 1 | 3 | 2007 | 0 | 1 | 1 | 2006 | 2 | 1 | 3 | 2005 | 2 | 0 | 2 | 2004 | 2 | 0 | 2 | 2003 | 6 | 0 | 6 |
To return to the timeline, click here.
Below are the most recent publications written about "Radiometry" by people in Profiles over the past ten years.
-
Okunieff P, Swarts SG, Fenton B, Zhang SB, Zhang Z, Rice L, Zhou D, Carrier F, Zhang L. Radiation Biological Toximetry Using Circulating Cell-Free DNA (cfDNA) for Rapid Radiation/Nuclear Triage. Radiat Res. 2024 07 01; 202(1):70-79.
-
Paschal HMP, Kabat CN, Martin T, Saenz D, Myers P, Rasmussen K, Stathakis S, Bonnen M, Papanikolaou N, Kirby N. Dosimetric characterization of a new surface-conforming electron MLC prototype. J Appl Clin Med Phys. 2024 Feb; 25(2):e14173.
-
Dogan N, Mijnheer BJ, Padgett K, Nalichowski A, Wu C, Nyflot MJ, Olch AJ, Papanikolaou N, Shi J, Holmes SM, Moran J, Greer PB. AAPM Task Group Report 307: Use of EPIDs for Patient-Specific IMRT and VMAT QA. Med Phys. 2023 Aug; 50(8):e865-e903.
-
Sunderland JJ, Graves SA, York DM, Mundt CA, Bartel TB. Multicenter Evaluation of Frequency and Impact of Activity Infiltration in PET Imaging, Including Microscale Modeling of Skin-Absorbed Dose. J Nucl Med. 2023 07; 64(7):1095-1101.
-
Sistani S, Babaeifar H, Khoramian D, Arani MN, Sarvizadeh M, Kalantari F, Ebrahimi A. BEAM MATCHING EVALUATION OF TWO SIMILAR LINEAR ACCELERATORS. Radiat Prot Dosimetry. 2023 Mar 17; 199(4):347-355.
-
Deshazer G, Narayanasamy G, Bimali M, Galhardo E, Kalantari F, Xia F, Pe?agar?cano J, Morrill S. A dosimetric comparative analysis of Brainlab elements and Eclipse RapidArc for spine SBRT treatment planning. Biomed Phys Eng Express. 2022 02 10; 8(2).
-
Donohoe KJ, Aloff J, Avram AM, Bennet KG, Giovanella L, Greenspan B, Gulec S, Hassan A, Kloos RT, Sol?rzano CC, Stack BC, Tulchinsky M, Tuttle RM, Van Nostrand D, Wexler JA. Appropriate Use Criteria for Nuclear Medicine in the Evaluation and Treatment of Differentiated Thyroid Cancer. J Nucl Med. 2020 03; 61(3):375-396.
-
Saenz DL, Li Y, Rasmussen K, Stathakis S, Pappas E, Papanikolaou N. Dosimetric and localization accuracy of Elekta high definition dynamic radiosurgery. Phys Med. 2018 Oct; 54:146-151.
-
Saenz DL, Astorga NR, Kirby N, Fakhreddine M, Rasmussen K, Stathakis S, Papanikolaou N. A method to predict patient-specific table coordinates for quality assurance in external beam radiation therapy. J Appl Clin Med Phys. 2018 Sep; 19(5):625-631.
-
Quevedo A, Luo G, Galhardo E, Price M, Nicolucci P, Gore JC, Zu Z. Polymer gel dosimetry by nuclear Overhauser enhancement (NOE) magnetic resonance imaging. Phys Med Biol. 2018 08 01; 63(15):15NT03.
-
Obeidat M, McConnell KA, Li X, Bui B, Stathakis S, Papanikolaou N, Rasmussen K, Ha CS, Lee SE, Shim EY, Kirby N. DNA double-strand breaks as a method of radiation measurements for therapeutic beams. Med Phys. 2018 Jul; 45(7):3460-3465.
-
McConnell KA, Marston T, Zehren BE, Lirani A, Stanley DN, Bishop A, Crownover R, Eng T, Shi Z, Li Y, Baacke D, Kirby N, Rasmussen K, Papanikolaou N, Gutierrez AN. Dosimetric Evaluation of Pinnacle's Automated Treatment Planning Software to Manually Planned Treatments. Technol Cancer Res Treat. 2018 01 01; 17:1533033818780064.
-
Narayanasamy G, Saenz DL, Defoor D, Papanikolaou N, Stathakis S. Dosimetric validation of Monaco treatment planning system on an Elekta VersaHD linear accelerator. J Appl Clin Med Phys. 2017 Nov; 18(6):123-129.
-
Stanley DN, McConnell KA, Kirby N, Guti?rrez AN, Papanikolaou N, Rasmussen K. Comparison of initial patient setup accuracy between surface imaging and three point localization: A retrospective analysis. J Appl Clin Med Phys. 2017 Nov; 18(6):58-61.
-
Paudel NR, Narayanasamy G, Han EY, Penagaricano J, Mavroidis P, Zhang X, Pyakuryal A, Kim D, Liang X, Morrill S. Dosimetric and radiobiological comparison for quality assurance of IMRT and VMAT plans. J Appl Clin Med Phys. 2017 Sep; 18(5):237-244.
-
Fallahpoor M, Abbasi M, Kalantari F, Parach AA, Sen A. Practical Nuclear Medicine and Utility of Phantoms for Internal Dosimetry: XCAT Compared with Zubal. Radiat Prot Dosimetry. 2017 Apr 25; 174(2):191-197.
-
Piert M, Shao X, Raffel D, Davenport MS, Montgomery J, Kunju LP, Hockley BG, Siddiqui J, Scott PJH, Chinnaiyan AM, Rajendiran T. Preclinical Evaluation of 11C-Sarcosine as a Substrate of Proton-Coupled Amino Acid Transporters and First Human Application in Prostate Cancer. J Nucl Med. 2017 08; 58(8):1216-1223.
-
Fallahpoor M, Abbasi M, Parach AA, Kalantari F. Internal dosimetry for radioembolization therapy with Yttrium-90 microspheres. J Appl Clin Med Phys. 2017 Mar; 18(2):176-180.
-
Zhang X, Penagaricano J, Narayanasamy G, Corry P, Liu T, Sanjay M, Paudel N, Morrill S. Helical tomotherapy to LINAC plan conversion utilizing RayStation Fallback planning. J Appl Clin Med Phys. 2017 Jan; 18(1):178-185.
-
Paudel NR, Shvydka D, Parsai EI. Thin-film CdTe detector for microdosimetric study of radiation dose enhancement at gold-tissue interface. J Appl Clin Med Phys. 2016 09 08; 17(5):500-508.
-
Narayanasamy G, Avila G, Mavroidis P, Papanikolaou N, Gutierrez A, Baacke D, Shi Z, Stathakis S. Comparison of composite prostate radiotherapy plan doses with dependent and independent boost phases. Australas Phys Eng Sci Med. 2016 Sep; 39(3):727-33.
-
Sharma S, Narayanasamy G, Przybyla B, Webber J, Boerma M, Clarkson R, Moros EG, Corry PM, Griffin RJ. Advanced Small Animal Conformal Radiation Therapy Device. Technol Cancer Res Treat. 2017 02; 16(1):45-56.
-
Pokhrel D, Sood S, Badkul R, Jiang H, McClinton C, Lominska C, Kumar P, Wang F. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy. J Appl Clin Med Phys. 2016 05 08; 17(3):277-293.
-
Meek M, Chang M, Lensing S, Deloney L. Radiation Exposure in Pregnant and Nonpregnant Female Interventional Radiology Workers. Radiol Technol. 2016 May; 87(5):574-8.
-
Liang X, Penagaricano J, Zheng D, Morrill S, Zhang X, Corry P, Griffin RJ, Han EY, Hardee M, Ratanatharathom V. Radiobiological impact of dose calculation algorithms on biologically optimized IMRT lung stereotactic body radiation therapy plans. Radiat Oncol. 2016 Jan 22; 11:10.
-
Narayanasamy G, Saenz D, Cruz W, Ha CS, Papanikolaou N, Stathakis S. Commissioning an Elekta Versa HD linear accelerator. J Appl Clin Med Phys. 2016 01 08; 17(1):179-191.
-
Saenz DL, Narayanasamy G, Cruz W, Papanikolaou N, Stathakis S. Pinnacle3 modeling and end-to-end dosimetric testing of a Versa HD linear accelerator with the Agility head and flattening filter-free modes. J Appl Clin Med Phys. 2016 01 08; 17(1):192-206.
-
Defoor DL, Vazquez-Quino LA, Mavroidis P, Papanikolaou N, Stathakis S. Anatomy-based, patient-specific VMAT QA using EPID or MLC log files. J Appl Clin Med Phys. 2015 May 08; 16(3):5283.
-
Narayanasamy G, Zalman T, Ha CS, Papanikolaou N, Stathakis S. Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance. J Appl Clin Med Phys. 2015 May 08; 16(3):5427.
|
People People who have written about this concept. _
Similar Concepts
People who have written about this concept.
_
Top Journals
Top journals in which articles about this concept have been published.
|